If you cannot find information about a compliance topic, please contact us for free support.
-
Policies & Procedures
- How to Submit Your SPRS Score: PIEE Step-by-Step Guide [2026 Update]
- CMMC Policies and Procedures: What Documentation You Need
- How to Write a System Security Plan: The Owner's Guide to the One Document That Gates Everything
- Creating a Plan of Action and Milestones for CMMC
- Documenting Evidence for CMMC Assessment
-
SPRS & Self-Assessment
-
CMMC Fundamentals
-
Contract Clauses & Flowdown
- DFARS and FAR Cybersecurity Clauses: What Each One Actually Requires
- What DFARS 252.204-7012 Requires, in Plain English
- DFARS 252.204-7019 vs 7020 vs 7021: What Each Clause Triggers
- FAR 52.204-21 and FCI: The 15 Basic Safeguarding Requirements
- DFARS flowdown requirements: Which Clauses You Must Pass to Your Subcontractors
- Flowdown: Which Clauses You Must Pass to Your Subcontractors
- Who Is Exempt from CMMC, and Why "We Only Make Parts" Usually Isn't
- What to Do When a DFARS Clause Appears in a Contract You Already Signed
- FAR 52.204-21 and FCI: The 15 Basic Safeguarding Requirements
-
Trigger Events & Urgent Situations
- Cybersecurity Questionnaire From Your Prime? Do This
- CUI Marked Drawings You Were Not Expecting? Do This
- Expired SPRS Score and a Bid Due? Fix It This Week
- Dropped Without CMMC? What a Prime Can Actually Do
- 90 Days to CMMC Compliance: What Is Really Possible
- DFARS 7021 Clause Found After Award? Read This First
- CMMC Compliant MSP? How to Verify What Yours Claims
- CUI in Commercial Microsoft 365: What to Do Now
- CMMC Level 2 Certification an RFP Wants? Bid Anyway
- CMMC Trigger Events: A Triage Guide for Contractors
-
CMMC Levels & Requirements
-
The 14 Control Families
- Access Control (AC)
- Awareness and Training (AT)
- Audit and Accountability (AU)
- Configuration Management (CM)
- Identification and Authentication (IA)
- CMMC Incident Response (IR)
- Maintenance (MA)
- Media Protection (MP)
- Personnel Security (PS)
- Physical Protection (PE)
- Risk Assessment (RA)
- Security Assessment (CA)
- System and Communications Protection (SC)
- System and Information Integrity (SI)
-
Implementation Roadmaps
-
Industry-Specific Guides
-
CMMC Documentation & Evidence
-
CMMC Costs & Budgeting
-
Technology & Tools
-
CMMC Training & Awareness
-
Supply Chain & Third-Party Risk
-
Incident Response & Breach Reporting
-
Common Mistakes & Failures
-
Advanced Topics & Level 2
-
Updates & Regulatory Changes
-
Artificial Intelligence (AI)
-
Comparisons & Alternatives
- GCC High vs GCC vs Commercial Microsoft 365 for CUI
- CMMC Compliance Options: Enclave, Environment or Service
- Enclave vs Full Remediation: Which CMMC Path Fits
- PreVeil vs GCC High for Small Defense Contractors
- CMMC Platform vs Consultant vs Doing It In House
- RPO vs C3PAO vs Consultant: Who Does What in CMMC
- CMMC Compliance Software for Small Manufacturers
- Azure Government vs AWS GovCloud for CUI Workloads
- Virtual Desktop Enclave vs Managed Laptops for CUI
- Free NIST 800-171 Tools vs Paid Platforms: The Gaps
- Build vs Buy Enclave: What In House Actually Costs
CMMC for Machine Shops
Specific CMMC Guide for Machine Shop Businesses
If your machine shop manufactures parts for defense contractors, you need CMMC certification to continue bidding on Department of Defense work. This “CMMC for Machine Shops” requirement applies whether you are a prime contractor or a subcontractor five tiers deep in the supply chain.
CMMC stands for Cybersecurity Maturity Model Certification, the DoD’s mandatory program requiring defense contractors to prove their cybersecurity meets federal standards.
Starting in 2025, contracting officers cannot award contracts to machine shops without the required CMMC certification level. This guide explains exactly what precision manufacturers need to know.
Why Machine Shops Need CMMC Certification
Machine shops occupy a critical position in the defense supply chain. When you manufacture components for military aircraft, naval vessels, weapons systems, or tactical vehicles, you handle sensitive technical information that adversaries want to steal.
This information includes:
- Technical drawings and specifications
- Material certifications and test results
- Tolerances and manufacturing processes
- Assembly instructions and quality requirements
- Delivery schedules and quantities
Even if you think your shop only makes simple parts, the aggregation of information across multiple orders can reveal sensitive details about defense programs. Foreign adversaries have targeted small manufacturers specifically because they often have weaker cybersecurity than large prime contractors.
Determining Your Required CMMC Level
Your required CMMC level depends on the type of information you handle, not your company’s size.
CMMC Level 1 applies to machine shops that only handle Federal Contract Information (FCI). FCI includes basic contract details like purchase orders, delivery schedules, and payment information. Level 1 requires 15 basic cybersecurity practices and allows annual self-assessment.
Federal Contract Information (FCI) is information provided by or generated for the government under contract that is not intended for public release.
CMMC Level 2 applies to machine shops that handle Controlled Unclassified Information (CUI). If you receive technical drawings marked with distribution statements, ITAR data, or specifications for defense components, you likely handle CUI. Level 2 requires 110 security controls from NIST SP 800-171 and typically requires third-party assessment.
Controlled Unclassified Information (CUI) is sensitive government information requiring protection under federal regulations but not classified as secret or top secret.
How to identify your level: Review your contracts for DFARS clause 252.204-7012. If present, you handle CUI and need Level 2. Also, check for CUI markings on drawings and specifications you receive from customers.
Common CMMC Challenges for Machine Shops
Machine shops face unique compliance challenges compared to office-based businesses.
Shop Floor Computers
CNC machines, CMMs, and other shop floor equipment often run outdated operating systems that cannot receive security updates. These systems may connect to networks to receive programs or upload inspection data. You must either isolate these systems from CUI or implement compensating controls.
Technical Drawing Storage
Many shops store customer drawings on shared drives without access controls. CMMC requires you to limit access to CUI based on job responsibilities and track who accesses sensitive files.
Email Security
Receiving drawings and specifications via email creates compliance challenges. Standard email services like Gmail or basic Microsoft 365 do not meet CMMC requirements for protecting CUI. You need either encrypted email solutions or secure file transfer methods.
Physical Security
Machine shops must control physical access to areas where CUI is stored or processed. This includes locking file cabinets containing drawings, restricting shop floor access to authorized personnel, and implementing visitor procedures.
Third-Party Software
CAD/CAM software, ERP systems, and quality management tools that store CUI must meet federal security requirements. Cloud-based solutions must achieve FedRAMP authorization or equivalent.
Step-by-Step Compliance for Machine Shops
Step 1: Identify Your CUI
Map exactly where sensitive information exists in your shop. This includes digital files, paper drawings, information stored in ERP systems, and data on shop floor computers. Document what information you receive, where you store it, and who can access it.
Step 2: Limit Your Scope
You do not need to apply CMMC controls to your entire IT environment. Create a defined boundary around systems that store, process, or transmit CUI. The smaller your scope, the less expensive compliance becomes.
Many machine shops create a separate network segment for handling CUI, keeping shop floor equipment and general business systems outside the compliance boundary.
Step 3: Address the 110 Controls
For Level 2, you must implement 110 security controls across 14 domains including access control, audit logging, incident response, and system protection. Some controls require technology solutions while others require documented policies and procedures.
Focus first on high-impact controls:
- Multi-factor authentication for all users accessing CUI
- Encryption for CUI at rest and in transit
- Endpoint detection and response on computers handling CUI
- Regular security awareness training for employees
- Documented incident response procedures
Step 4: Create Required Documentation
CMMC requires a System Security Plan (SSP) describing how you implement each control. You also need policies and procedures for access control, incident response, and other security domains. Machine shops often underestimate the documentation burden.
Step 5: Conduct Gap Assessment
Before your official assessment, identify gaps between your current state and CMMC requirements. Address critical gaps before scheduling your certification assessment.
Step 6: Schedule Your Assessment
For Level 2, contact a Certified Third-Party Assessment Organization (C3PAO) to schedule your assessment. Assessment availability is limited, so plan ahead.
C3PAO stands for Certified Third-Party Assessment Organization, companies authorized by the Cyber AB to conduct official CMMC assessments.
Costs for Machine Shop Compliance
Compliance costs vary significantly based on your starting point and scope size. Small machine shops with minimal existing security typically spend $30,000 to $100,000 achieving Level 2 compliance, including technology, consulting, and assessment fees.
Cost factors include:
- Current cybersecurity maturity
- Number of systems in scope
- Need for new technology solutions
- Internal versus external resources
- Consulting and assessment fees
Many shops reduce costs by minimizing scope, using managed security services, and leveraging compliance platforms that streamline documentation.
Key Takeaways for Machine Shops
Machine shops handling DoD work must achieve CMMC certification starting in 2025. Your required level depends on whether you handle FCI (Level 1) or CUI (Level 2). Shop floor equipment, technical drawings, and email handling create unique challenges for precision manufacturers.
Start by identifying where CUI exists in your environment, then limit your compliance scope to reduce costs. Budget adequate time for implementation—most shops need 6-12 months to achieve Level 2 certification.
Keep reading
More in Industry-Specific Guides
- CMMC for Aerospace Subcontractors →
- CMMC for Managed Service Providers →
- CMMC for Small Businesses →
- CMMC for Universities & Research Labs →
- What is Controlled Unclassified Information (CUI)? →
Free tools
Get to an honest number faster
You will run this more than once: after any material change to your environment, and again before every annual affirmation. Both are free, and both are yours to keep.
Neither is a certified assessment, and neither pretends to be.
Official sources
The audit is gone. The liability isn't.
Greypike runs the environment your CUI lives in and owns the compliance outcome that proves it's protected. If you are not certain your environment supports the score sitting in SPRS next to your CAGE code, that is the conversation to have.
Talk to Greypike about SPRS Attestation AssuranceGreypike Inc.
SBA-certified Veteran-Owned Small Business
Cyber AB Registered Practitioner (RP) and Registered Practitioner Advanced (RPA) on staff
CAGE 9WVS6 · UEI N6CJNGDARFM5